P M T

Flat roof photovoltaic mounting system

PMT EVO 2.1 EW – Simple. Flexible. Safe.

As a photovoltaic mounting system, PMT EVO 2.1 EW is the best solution for flat roofs with an east-west elevation of the modules. With PMT EVO 2.1, PMT focuses on safety and quality as well as short installation time and cost efficiency.
request now
Scroll
EVO 2.1

Safe & fast installation

We continue to rely on our tried-and-tested click technology, enabling fast and error-free installation for everyone.

It’s all in the overall package

The system is suitable for all framed solar panels on the market, has a lightning current carrying capacity and a low-resistance connection.

PRODUCT FEATURES

Innovative click connections, smart cable routing and variable module dimensions make the installation of PMT EVO 2.1 EW uncompromisingly simple. Discover the many other advantages of our east-west elevation.

Simplified installation, certified safety and top quality performance for your flat roof projects

The east-west mounting system is suitable for almost all roof surfaces with a pitch between 0 and 10° and can be used in almost all European wind and snow load zones. In addition, there is both a 10° and a 15° variant.

Thanks to the innovative click connections of the PV mounting system flat roof east-west, the system can be installed safely and in just a few steps.

We were one of the first companies to receive general building authority approval from the German Institute for Building Technology for our aerodynamic flat roof systems. This certification confirms our technical and qualitative standards.
The east-west mounting system is suitable for almost all roof surfaces with a pitch between 0 and 10° and can be used in almost all European wind and snow load zones. In addition, there is both a 10° and a 15° variant.

Thanks to the innovative click connections of the PV mounting system flat roof east-west, the system can be installed safely and in just a few steps.

We were one of the first companies to receive general building authority approval from the German Institute for Building Technology for our aerodynamic flat roof systems. This certification confirms our technical and qualitative standards.
Revolutionary design
Click technology

Safe and simple technology

The PV mounting system PMT EVO 2.1 East-West is easy to install thanks to interchange-proof click connections. The upgraded ProPlates are also mounted on the profiles with a simple click.
Tested and safe

Lightning current carrying capacity

Our flat roof systems are inherently capable of carrying lightning currents and can therefore be integrated into the lightning protection concept of the building. The lightning current carrying capacity of the east-west elevation has been verified in accordance with DIN EN 62561 (VDE 0185-561-1):2013-02.
PMT Quality

Safety first

We regularly test and verify our PV east-west elevation within the scope of wind tunnel tests, experimental component examinations and on the basis of current DIN standards. Additional optional components such as ridge couplings and Solmont connections increase the safety factor.
Module independence

Variable dimensions possible

In principle, our photovoltaic mounts are suitable for all common modules on the market. PMT EVO 2.1 covers module areas up to 2.4sqm.
Ballasting

Standardised ballast stones

Thanks to the standardised ballast stones, our east-west elevation allows for simple and quick installations of ballasting with our ballast clamps. The stones, each weighing 15 kg, are already integrated in the your PMT PLAN project. Our mounting systems also have a significantly lower ballast requirement compared to other substructures.
Perfect support

Adapts to the surface

The continuous PMT EVO 2.1 floor profiles are supplemented by the new ProPlates. These offer an improved bearing surface and thus create relief for various roof substrates.
Simple cable laying

Invisible integration in the system

Thanks to the integrated cover of the east-west elevation, the individual cables are no longer visible. For fixation, the system contains a 3-fold edge clip receptacle. Depending on the requirements of the installation, separation distances of more than 150 mm can be maintained. The cables can be laid separately according to DC +/-.
Universal module and ballast clamp

It is going up high

No matter which modules you use with the PMT East-West elevation, our universal mounting covers clamping ranges between 30 and 50 mm.
Accessories from PMT

The optimal supplement

Depending on your requirements, we can offer our proven accessories for our east-west mounting system. Whether ridge coupling lengthwise and crosswise, route connection, mechanical fastening points, side covers or trapezoidal sheet adapters – depending on the requirements of your project, we have the right extra.
Technische Daten
Components
Accessories
Downloads
Application type
Flat roof up to 5° roof pitch
(special projects up to 10° possible)
Angle of incline
10° and 15°
Alignment
East-west installation
Roof covering
Foil, bitumen, sheet metal, concrete
Row Spacing
from 2205 mm to 2882 mm (depending on module width and system variant)
Weight
System surface load incl. module and ballast from 9.5 kg/m²
ProPlates
Recycled PE-HD plastic plate (high-density polyethylene), no plasticiser migration
Certificates
Lightning current carrying east-west mounting system according to DIN EN 62561 (VDE 185-561-1):2013-02

General building authority approval Z-14.4-790 for the complete system

Low-resistance connection verification (>1 Ω) for the entire system
Material

Aluminium EN-AW-6063-T3
Stainless steel A2-70
High density polyethylene PE-HD Recyclate

Modules
All common PV module sizes:
Width: 985-1300 mm,
Length: 1550-2400 mm,
Height: 30-50mm,
(special sizes possible on request)
Base Profile
Base Profile
EVO 2.1 HBP Type 2043
EVO 2.1 HBP Type 2180
EVO 2.1 HBP Type 2280
EVO 2.1 HBP Type 2380
EVO 2.1 HBP Type 2480
ProPlate
ProPlate
ProPlate
Base
Base
10° Components:
EVO B10 Type 75
EVO B10 M6 Type 75

15° Components:
EVO B15 Type 75
EVO B15 M6 Type 75
Cross- and Ballast Strut
Cross- and Ballast Strut
EVO QBS
Length: from 1568 bis 2393 mm
Cross Strut Connector
Cross Strut Connector
EVO QSV Typ 390
EVO QSVU Typ 1180
Tower
Tower
10° Component: EVO T10 Typ 75
15° Component: EVO T15 Typ 75
Connector Base Profile
Connector Base Profile
EVO V1BP Type 127
EVO V2BP Type 267
EVO 2.1 V3BP Type 367
EVO 2.1 V4BP Type 567
Base Profile Edge
Base Profile Edge
EVO 2.1 AEBP Typ 61
Distance Gauge
Distance Gauge
EVO AL univ.
Screw
Screw
M8x30
Mid Clamp
Mid Clamp
MK Typ 40
End Clamp
End Clamp
EK Typ 35
Click Guide
Click Guide
EVO 2.1 Click Guide HBP 2043
EVO 2.1 Click Guide HBP 2180
EVO 2.1 Click Guide HBP 2280
EVO 2.1 Click Guide HBP 2380
EVO 2.1 Click Guide HBP 2480
ADAPTER FOR CROSS AND BALLAST STRUTS
ADAPTER FOR CROSS AND BALLAST STRUTS
EVO MAQBS Type 75
Mid Support
Mid Support
10° Component: EVO MAG EW10
15° Component: EVO MAG EW15
Side Cover
Side Cover
10° Component: 
EVO SDR EW10
EVO SDL EW10

15° Component:
EVO SDR EW15
EVO SDL EW15
Cable Duct Cover
Cable Duct Cover
EVO 2.1 KD Typ 160
EVO 2.1 KD Typ 280
EVO 2.1 KD Typ 400
EVO 2.1 KD Typ 600
Cable Tray Base Profile
Cable Tray Base Profile
EVO 2.1 TRA T Typ 400
EVO 2.1 TRA T Typ 700
EVO 2.1 TRA T Typ 1000
EVO 2.1 TRA B Typ 400
EVO 2.1 TRA B Typ 700
EVO 2.1 TRA B Typ 1000
EVO 2.1 TRA Typ 195
EVO 2.1 TRA Typ 400
Ridge Connector
Ridge Connector
EVO 2.1 FV Typ 547
USO
USO
10° Component: EVO USO EW10 Typ 100
15° Component: EVO USO EW15 Typ 100
Solmont
Solmont
Available with different coatings adapted to the roofing membrane
Adapter for Line Connection
Adapter for Line Connection
EVO TRQBS L Typ 150
EVO TRQBS R Typ 150
Ballast Tub
Ballast Tub
EVO 2.1 BW V01 Typ 70
EVO 2.1 BW V01 Typ 70 – divided Tub
EVO 2.1 BW V02 Typ 70
EVO 2.1 BW V02 Typ 70 – divided Tub
Support Solar Sensor
Support Solar Sensor
10° Components:
EVO TBES L Typ 10°
EVO TBES R Typ 10°

15° Components:
EVO TBES L Typ 15°
EVO TBES R Typ 15°
Trapezodial Sheet Adapter
Trapezodial Sheet Adapter
EVO TBH Typ 208
Screw
Screw
M8 x 16
Product Datasheet PMT EVO 2.1 EW
(1.03 MB)
zum Download
Technical Datasheet PMT EVO 2.1 EW
(1.15 MB)
zum Download
I have a question regarding this product.
Contact

YOU ARE PLANNING A PROJECT?
WE WOULD BE HAPPY TO ADVISE YOU

IHRE ANSPRECHPARTNERIN
Nadine Fiedler
Key Account Manager
+ 49 (0) 9225 95500 project@pmt.solutions jetzt kontaktieren
Partner

FAQ

Häufige Fragen

How many click variants will there be?

There are three different cladding variants for each main floor profile – standard, partial and full-surface.

How much better will the load transfer to the roof be (in percent)?

The contact area of the ProPlate of the EVO 2.1 system is on average approx. 40 % larger than that of the high-tech building protection mats of the EVO 2.0 system. This is an average value, taking into account all track lengths and all bonding and cladding variants.

What about the coefficient of static friction, also on bitumen?

We recommend measuring the static friction coefficient for each project using the PMT measurement protocol and the PMT static friction coefficient backpack.

A value of 0.5 is set as the default value in the PMT PLAN planning tool; it is essential to verify this on a project-specific basis.

Are there migration results? Are foil manufacturers involved?

The ProPlate plastic plate has been tested on various roof sealants (PVC, bitumen, EPDM, FPO/TPO).

You can request more detailed information at any time via your contact person or via project@pmt.solutions.

How much does the EVO 2.1 cost?

You can find the system prices in the corresponding price list. If you do not have this, you can request it at any time from your direct contact person or project@pmt.solutions.

Can 2.1 be installed with 2.0 in one project?

PMT does not recommend mixing the different system variants EVO 2.0 and EVO 2.1.

Can the 2.1 rail for trapezoidal sheet be used with the TBSH?

The installation for trapezoidal sheet metal with the TBSH can be carried out as usual.

Can Multi Monti continue to be offered?

The Multi Monti system (fixing the main floor profiles to the ballast stones using Multi Monti screws) can be installed as usual. This is a take-over article.

What solution do we offer on trapezoidal sheet metal against the bead?

Installation for trapezoidal sheeting with the TBH type 208 can be carried out as usual – both the main floor profile and the TBH type 208 are take-over components that can be installed as usual.

What is the heat and cold resistance of the ProPlate?

The ProPlates have been tested and approved for temperatures between -20°C and +80°C.

Is a connection from 1° still recommended?

We further recommend a connection to the roof from a roof pitch of 1° due to the thermally induced caterpillar effect. For this, we recommend the BSW information paper, which we will be happy to provide to you on request.

What is the material durability of the polymer plates?

For this purpose, continuous abrasion tests were carried out for a service life of 25 years. Furthermore, UV tests were carried out to ensure the corresponding durability.

If you need more detailed information on this, you can request it from your direct contact or via project@pmt.solutions.

Is there a chemical and mechanical approval on bitumen roofing?

The ProPlate plastic plate has been tested on various roof sealants (PVC, bitumen, EPDM, FPO/TPO).

You can request more detailed information at any time via your contact person or via project@pmt.solutions.

What material is the ProPlate made of?

PE-HD recyclate (high density polyethylene – recyclate)

What are the guarantee conditions?

The warranty conditions are available under Downloads.

Can I plan the system in the tool?

EVO 2.1 can be planned via PMT PLAN just like EVO 2.0. If you have any detailed questions, please do not hesitate to contact us at project@pmt.solutions.

How do I know where to put the ProPlates?

The application of ProPlates to the main floor profiles can be found in the planning documents. There are three different ways to use ProPlates per main floor profile: Standard, Partial or Full.

The exact placement of the ProPlates can be found in the corresponding data sheet. Our Click Guide installation help, which can be adapted to the corresponding type of clicking, is another aid to correct clicking on the roof.

zu PMT Plan

Back to top